Spectrophotometer concentration and standard curve

General use[ edit ] In more general use, a calibration curve is a curve or table for a measuring instrument which measures some parameter indirectly, giving values for the desired quantity as a function of values of sensor output. For example, a calibration curve can be made for a particular pressure transducer to determine applied pressure from transducer output a voltage. The data - the concentrations of the analyte and the instrument response for each standard - can be fit to a straight line, using linear regression analysis.

Spectrophotometer concentration and standard curve

Other techniques, such as HPLC, are also acceptable if total protein recovery is demonstrated. Many of the total protein assay methods described below can be performed successfully using kits from commercial sources. This property is the basis of Method 1.

Determination of Inoculum for the AET

Protein determination at nm is mainly a function of the tyrosine and tryptophan content of the protein. If the buffer used to dissolve the protein has a high absorbance relative to that of water, there is an interfering substance in the buffer.

This interference can be compensated for when the spectrophotometer is adjusted to zero buffer absorbance. The results may be compromised if the interference results in a large absorbance that challenges the limit of sensitivity of the spectrophotometer. Furthermore, at low concentrations protein can be absorbed onto the cuvette, thereby reducing the content in solution.

This can be prevented by preparing samples at higher concentrations or by using a nonionic detergent in the preparation. To obtain accurate results, the response should be linear in the range of protein concentrations to be assayed.

If the proteins in solution exist as particles comparable in size to the wavelength of the measuring light to nmscattering of the light beam results in an apparent increase in absorbance of the test specimen. To calculate the absorbance at nm due to light-scattering, determine the absorbances of the Test Solution at wavelengths of,, and nm.

Using the linear regression method, plot the log of the observed absorbance versus the log of the wavelength, and determine the standard curve best fitting the plotted points. From the graph so obtained, extrapolate the absorbance value due to light-scattering at nm.

Subtract the absorbance due to light-scattering from the total absorbance at nm to obtain the absorbance value of the protein in solution. Filtration with a filter having a 0. The Folin-Ciocalteu's phenol reagent reacts primarily with tyrosine residues in the protein, which can lead to variation in the response of the assay to different proteins.

Because the method is sensitive to interfering substances, a procedure for precipitation of the protein from the test specimen may be used.

Where separation of interfering substances from the protein in the test specimen is necessary, proceed as directed below for Interfering Substances prior to preparation of the Test Solution. The effect of interfering substances can be minimized by dilution, provided the concentration of the protein under test remains sufficient for accurate measurement.

An appropriate buffer will produce a pH in the range of Dissolve 10 g of sodium carbonate in water to a final volume of 50 mL, and mix.

Dedicated to the improvement of regulatory science and compliance

Slowly pour the sodium carbonate solution into the copper sulfate solution with mixing. Prepare this solution fresh daily.Nov 12,  · A calibration curve is a method used in analytical chemistry to determine the concentration of an unknown sample solution.

It is a graph generated by experimental means, with the concentration of solution plotted on the x-axis and the observable variable — for example, the solution’s absorbance — plotted on the y-axis. 1. SCOPE. Scope. This specification covers single component, polymeric flattened, chemical agent resistant, aliphatic polyurethane coating for use as a finish coat on military tactical equipment, which includes ground, aviation and related support assets.

Once your statistical analyses are complete, you will need to summarize the data and results for presentation to your readers. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration.

A calibration curve is one approach to the problem of instrument calibration; other standard approaches may mix the standard into the unknown, giving. By constructing a standard curve of known concentration and measured absorbance samples. How is a standard curve constructed? by measuring the absorbances of samples of known concentrations or amounts and plotting the results on graph paper (absorbance on the ordinate and amount or concentration of compound on the abscissa).

Spectrophotometer; the finding of protein concentration of an unknown sample of BSA, and by using the standard curve. Abstract A spectrophotometer’s purpose is to use colors of the light spectrum to determine the concentration of light absorbing molecules in a solution.

Spectrophotometer concentration and standard curve

(p) In this particular.

The Pharmaceutics and Compounding Laboratory :: UV/VIS Assays